Pinless Moisture Meters

first_imgThe cornerbead throws off the meter readingsI confirmed this phenomenon with my own Delmhorst pinless moisture meter. Image #4 shows a comparative reading of 8 where the drywall has just an empty framing cavity behind it. Image #5 shows a reading of 35 at the corner. In its 2.5-inch by 3.5-inch sensor pad, the meter is including the metal cornerbead. The reading should not be interpreted to mean that the moisture level is higher in this location.To “ground” those numbers, I took a moisture content reading with my Delmhorst BD2100 pin-type moisture meter (see Image #6) and got a reading of 0.3. What does that mean?It turns out that Delmhorst is the only moisture meter manufacturer to have done the extensive testing necessary to develop a true scale for the percent moisture content by weight for gypsum wallboard. A moisture content by weight of 0.3% is approximately what the equilibrium moisture content would be for air of 50% relative humidity at an air temperature of about 70°F. The Delmhorst manual indicates that % moisture content for gypsum wallboard up to approximately 0.5% is acceptable, 0.5% to 1% is cautionary, and greater than 1% is “unacceptable” (with the main consideration being whether or not the drywall can be painted or wallpapered). As a baseline, take a reading from a surface known to be dryWhat about using pinless moisture meter readings (by either % or the unit-less comparative scale) for determining moisture content as it relates to mold growth? The Ryobi moisture meter clearly states that their “…pinless moisture meter detects moisture levels which can contribute to mold growth.”However, the manual for the Delmhorst ProScan pinless moisture meter is much more circumspect regarding the use of this meter relative to mold growth. The manual states, “ProScan is a useful tool in identifying moisture in walls, ceilings and floors in a water restoration or mold remediation. In order to establish pre-loss conditions, find an area of the building that was not damaged and take several readings on various materials. This will provide you with a ‘dry standard’ or target moisture levels when drying damaged areas.“Take several readings on each wall. Pay special attention near the base, around doorjambs, electrical and plumbing fixtures, and other places where water may have entered. Use the meter continuously during the drying process to monitor drying progress.” In addition to acting as GBA’s technical director, Peter Yost is the Vice President for Technical Services at BuildingGreen in Brattleboro, Vermont. He has been building, researching, teaching, writing, and consulting on high-performance homes for more than twenty years. An experienced trainer and consultant, he’s been recognized as NAHB Educator of the Year. Do you have a building science puzzle? Contact Pete here. You can also sign up for BuildingGreen’s email newsletter to get a free report on insulation, as well as regular posts from Peter. Extending the Reach of a Moisture MeterMeasuring (and Understanding) HumidityTools of the Trade: Moisture Meters Video: NAHB Train the Trainer Video Series: Tools of the TradeEssential Energy-Audit EquipmentDiagnostic Tools for Energy-Minded RemodelersMoisture Sources, Relative Humidity, and MoldWhy Is It So Humid In Here? I got a call the other day from a builder client, who said, “Hey Peter, a new homeowner of mine is super-worried about moisture and mold and is getting scary readings with his pinless moisture meter. Help!”Pinless moisture meters read from the surface of any material, using an electromagnetic field. Feedback from this field provides information to estimate moisture content. These meters are called “capacitance-based” meters, while pin-type moisture meters are called “resistance-based” meters.center_img Image #2 (below) shows the Ryobi meter reading 0.00% and set for “Wall.” Image #3 shows the same meter reading “78% moisture content” with the alarm going off. You can see that the meter is right on an outside corner of the drywall. What do you think it is reading?Yup — the meter is picking up the metal cornerbead less than ½ inch behind the joint compound at the corner. The moisture content at the corner is no different than it is on the rest of the wall. To be fair, there is this note in the Ryobi manual: “The presence of metal behind the wall may interfere with the reading…” Using pinless moisture metersThe bottom line:Like most moisture meters, pinless meters work best for the material they were originally designed for: wood.With any material less than ¾ inch in thickness, be very careful about what is behind the material — be it air, a stud, or (especially) any metal, including fasteners, steel studs, or cornerbead.Use the readout numbers only comparatively, comparing the readings of materials that you know are “dry” to the readings from areas you are assessing. Take lots of readings and use the pattern of readings to augment other information or patterns that may suggest elevated moisture content, like staining, material softness, or odor. Moisture content readings are given as a percentageMy builder’s homeowner has a Ryobi E49MM01 pinless moisture meter. The Ryobi manual starts off at the top with this information: “The pinless moisture meter detects moisture levels which can contribute to mold growth. This product detects and displays the percentage of moisture present in softwoods, hardwoods, drywall, and masonry.”So, here comes the first problem: % what? Moisture meters are set up to measure % moisture by weight, so that a reading of 13% for wood means that the moisture content of the wood is 13% by weight. If you dried all of the moisture out of the wood, the wood would weigh 13% less. But when you switch any meter over to the “reference” scale, the meter is no longer measuring or reporting moisture content by weight; it is simply assigning a comparative moisture content between 1 and 100, with lower numbers representing less moisture and higher numbers higher moisture content. RELATED ARTICLES last_img

Leave a Reply

Your email address will not be published. Required fields are marked *